  Step 1: Pipe cutting
Cut the pipe vertically and precisely with a pipe cutter.
  Step 2: Rounding and beveling
Round and bevel the end holes with the Rifeng reamer.
  Step 3: Inserting
Choose the right size sleeved-fitting for the pipe, then aim the pipe end at the ring-shape hole of the fitting integrated with sleeve and slide the fitting insert into the pipe until it reaches the plastic block. Check the inserting depth by looking through the inspection holes on the sleeve shoulder to ensure that the pipe is completely inserted.
 
Step 4: Pressing
1. Selecting jaw.
2. Installing jaw on to the Tool.
3. Adjusting the Pressing Tool.
4. Open the Pressing Tool and position the tool right onto the sleeve.
5. Close the handles until the two touch points on the handles touch each other.
6. While the jaw is completely closed, the handles will be self-locked. Open the handles and remove the pressing tool from the fitting and installation is accomplished.
 
Notice:
* This installation manual is especially for the 14-32(mm) piping systems.
* For your safe connection, Rifeng pipes should be connected with approved fittings recommended by Rifeng.
 
 